📢 Clearance Deals

Shop Now

SAKURA HD100RF-L-WH vs HD10FF-L Comparison

Compare other products

Side by side

HD100RF-L-WH HD10FF-L

  • HD100RF-L-WH lists thermal efficiency of 90.8% at 100% load and 94.6% at 50% load; HD10FF-L lists 90.4% and 95.0%, respectively.
  • Rated heat input is 22.7 kW for HD100RF-L-WH versus 22.1 kW for HD10FF-L.
  • Measured heat input is 23.6 kW for HD100RF-L-WH versus 22.0 kW for HD10FF-L.
  • HD100RF-L-WH explicitly lists seasonal temperature adjustment. HD10FF-L explicitly lists electronic ignition and suitability for replacing older Panasonic models; these features are not specified for the other model.
項目/itemHD100RF-L-WHHD10FF-L
Model listed in specificationsHD100RF-LHD10FF-L
Gas typeLiquefied Petroleum Gas (LPG)
ColourWhite
Country of originTaiwan; energy-label place of manufacture: Taiwan, China
Exhaust methodRear/back flue
Hot water flow rate10 L/min at a 25°C temperature rise
Dimensions (H × W × D)570 × 350 × 138 mm
Weight16 kg
Energy labelGrade 1
Thermal efficiency at 100% load90.8%90.4%
Thermal efficiency at 50% load94.6%95.0%
Rated heat input22.7 kW22.1 kW
Measured heat input23.6 kW22.0 kW
Gas consumption, as listed in specificationsMaximum: 22.7 kW; minimum: 7.6 kW
Power supplyAC 220 V / 50 Hz
Power consumption40 W
Minimum operating water pressure20 kPa
Recommended water pressure80–700 kPa
Digital thermostatic control✅
Temperature memory✅ Saves the previous temperature setting
LED temperature display✅
Temperature adjustment range35°C–60°C
Seasonal temperature adjustment✅ Adjusts burner output according to climate changes❌ Not specified
Electronic ignition❌ Not specified✅
Suitability for replacing older Panasonic models❌ Not specified✅
Japanese JIA safety certification✅
GU Mark✅ Hong Kong EMSD GU Mark, described as a safety certification✅ GU Mark, described as an energy efficiency label
Warranty3-year free parts warranty
Standard installation scopeOld-unit removal, excluding disposal; gas and water pipe connections within 1 foot; power cord connection within 3 feetOld-unit dismantling, excluding removal; gas and water pipe connections within 1 foot; power cable connection within 3 feet
Customer-provided power point required❌ Not specified✅

The above information is analyzed and compared by AI, and the content may not be 100% accurate. If you have any questions, please contact our sales staff or the brand for inquiries.