| Item | 30BWBH/W | TTH2150 |
| Core functions | Heating, drying, circulation and ventilation | |
| Named operating modes | Heating, Dry Hot (clothes drying), Dry Cool (circulation), Ventilation | Heating, ventilation, drying, circulation |
| Care Mode | ✅ Automatic transition among Heating, Dry Hot and Ventilation | ❌ Not specified |
| Preset programs | Warm Bath, Dry Cloth, Refresh, 24Hr Vent | Not specified |
| Installation design | Window mount; duct installation not required | Pull-out design for flexible installation and easier maintenance |
| Dimensions (W × H × D) | 320 × 350 × 230 mm | 254 × 254 × 218 mm |
| Installation hole (W × H) | 275 × 300 mm (10.82 × 11.81 inches) | 210 × 219 mm |
| Net weight | 5.5 kg | 4.7 kg |
| Colour | Pearl white | |
| Surface material | Not specified | Tempered glass |
| Heater type | PTC ceramic | Not specified |
| Maximum power | Maximum wattage: 1,440 W | Maximum rated power: 1,350 W |
| Ventilation power | 38 W | Not specified |
| Power source specification | 13 A | Not specified |
| Ventilation airflow | 260 m³/hour | Maximum: 100 m³/hour |
| Noise level | Ventilation/heating: 45 dB | Maximum: 56 dB |
| Filter | Alleru-buster filter; helps trap allergens | Graphene active carbon filter; deodorization and antibacterial protection |
| ION negative ion function | ❌ Not specified | ✅ |
| Control | Wireless remote control | Wireless LED remote control |
| Vertical airflow adjustment | Automatic or fixed swing | Not specified |
| Horizontal airflow adjustment | Manual adjustment | Not specified |
| Heating / Dry Hot / Dry Cool fan speeds | High / Low | Not specified |
| Ventilation fan speeds | High / Medium / Low | Low / High / Strong |
| Timer range | 5–720 minutes | Not specified |
| Maximum heating operation time | 180 minutes | Not specified |
| Maximum Dry Hot operation time | 360 minutes | Not specified |
| Ventilation operation | Continuous operation | 24-hour ventilation function |
| Dry Cool operation | Continuous operation | Not specified |
| Ventilation delay | Not specified | 15 minutes |
| Water resistance rating | Not specified | IPX4 |
| Heating overload protection | ❌ Not specified | ✅ Dual protection mechanism |
| Operating temperature | Not specified | 0–45°C |
| Motor / blade configuration | 1 motor / 1 blade | Not specified |
| Exhaust outlets | 1 | Not specified |
| Warranty | 1 year | 3-year parts warranty |
| Usage and order restrictions | Not specified | Not for industrial or commercial use; industrial and commercial orders/addresses are not accepted |